| Model |
Volts |
Amps |
Element Resistance |
High Setting |
Low Setting |
| AE3.4* |
120-110 |
27 |
2x8Ω |
3.4-3.0kW |
-- |
| AE7.2 |
240-220 |
30 |
2x16Ω |
7.2-6.1kW |
-- |
| AE7.2 |
240-220 |
15 |
1x12Ω |
-- |
3.6-3.05kW |
| AE9.5 |
240 |
40 |
2x12Ω |
9.5kW |
-- |
| AE9.5 |
240 |
20 |
1x12Ω |
-- |
4.75kW |
| AE9.5 |
208 |
35 |
2x12Ω |
7.1kW |
-- |
| AE9.5 |
208 |
18 |
1x12Ω |
-- |
3.5kW |
| AE12** |
240 |
50 |
-- |
12.0kW |
-- |
Temperature Rise (°F) at Flow Rate (GPM)
| Model |
.50GPM |
.75GPM |
1.0GPM |
1.5GPM |
2.0GPM |
| AE3.4* |
41°F |
28°F |
20°F |
n/a |
n/a |
| AE7.2 |
96°F |
63°F |
48°F |
32°F |
24°F |
| AE7.2 |
48°F |
32°F |
24°F |
16°F |
12°F |
| AE9.5 |
n/a |
84°F |
64°F |
42°F |
32°F |
| AE9.5 |
n/a |
42°F |
32°F |
21°F |
16°F |
| AE9.5 |
n/a |
64°F |
48°F |
32°F |
24°F |
| AE9.5 |
na/ |
32°F |
24°F |
16°F |
12°F |
| AE12** |
72°F |
72°F |
72°F |
52°F |
42°F |
Thermostatic Model AE12 - Note:
Maximum degree rise is based on incoming water temperature of 50°F.
All models are only 6 lbs.
GPM = gallons per minute.
NOTE: Average hand washing temperature is 105° F.
*AE3.4 includes a 0.5 GPM faucet aerator for optimal performance.
** Designed for operation on 240 volt only. High/Low kW settings possible within some models.