Do not install the unit in a room where there is a chance of freezing.
Check the pressure of the main water supply. To operate correctly, the unit needs the following running pressures:
Minimum: 15 psi (1 Bar) Maximum: 150 psi (10 Bar)
Energy Factor
AE115: 0.95AE125: 0.95
Efficiency
AE115: 95%AE125: 95%
Weight
AE115: 20 lbs.AE125: 22 lbs.
Dimensions
AE115: 15.5" x 15.25" x 4.5"AE125: 15.5" x 15.25" x 4.5"
Water Fittings
AE115: ¾" male NPTAE125: ¾" male NPT
Volts
AE115: 240/208vAE125: 240/208v
Kilowatts
AE115: 17.25/13kwAE125: 26.85/20kw
Amps*
AE115: 80In US (2 x 40 amps)In Canada** (1 x 80 amps)AE125: 120In US (3 x 40 amps)In Canada** (1 x 120 amps)
Wire Size
AE115: In US - Min. #8 AWG (4 conductors & ground)In Can.** - Min. #4 AWG (2 conductors & groundAE125: In US - Min. #8 AWG (6 conductors & ground)In Can.** - Min. #2 AWG (2 conductors & ground)
Flow Rates
AE115: 45°F rise @ 2.6 gpm50°F rise @ 2.3 gpm60°F rise @ 2.0 gpm 70°F rise @ 1.7 gpm 80°F rise @ 1.5 gpm AE125: 45°F rise @ 4.0 gpm50°F rise @ 3.7 gpm60°F rise @ 3.0 gpm 70°F rise @ 2.6 gpm 80°F rise @ 2.2 gpmNOTE: The unit will not provide an output temperature above 131°F.
*Recommended service to home for AE115 is 150 amps; 200 amps for AE125.**In Canada, unit must be wired to a single breaker. AE Canada Kit required and included. Always check local codes.