2400EO Technical Support
2400EO Technical Support
 
   
   Specifications
specs  

Power Input

Natural Gas: 35,000 - 175,000 Btu
LP Gas: 31,000 - 175,000 Btu

Minimum Flow to Activate

0.8 gallons per minute (gpm)

Flow Rates

45°F rise @ 6.4 gpm
55°F rise @ 5.2 gpm
65°F rise @ 4.5 gpm
75°F rise @ 3.9 gpm
90°F rise @ 3.2 gpm

Energy Factor

.80

Thermal Efficiency

87%

Dimensions

Height: 23.5"
Width: 15.75"
Depth: 8.5"

Weight

47 lbs.

Modulating Gas Valve

Yes

Ignition

Electronic

Accessories

Wireless Remote Thermostat

Life Expectancy

20+ years

   Installation Specifications

Gas Connections ¾" Male NPT
Water Connections ¾" Male NPT
Natural Gas Pressure Minimum: 5" WC
Maximum: 14" WC
LP Gas Pressure Minimum: 11" WC
Maximum: 14"
Water Pressure Minimum: 30 PSI
Maximum: 150 PSI
Electrical Supply 120 volt (plugs in)

 

 

 

 

 

 

 

tech_specs_125bo.gif

 Ref.DescriptionMin. distances
A, B, CDirectly below an opening; operable windows, doors and any fresh air openings.4 ft.
DFrom any adjacent wall.4 ft.
EBelow a gutter, sanitary pipework, eaves or overhang.3 ft.
FAbove ground.1 ft.
GFrom a gas meter or gas regulator3 ft.
   
2400EO Tech Support
 

Note: Specifications and product information subject to change without notice.